Home | Locations |   Power Quality Profile   | More About Us  | Products  | Power Quality Training | Power Quality Request Form

Back

BIDHISS I Specifications

 

Model

Power Rating

Voltage

Load Capacity Amps

Conditioner Protection Method*

Load Regulation +/-  %

Efficiency

Number of Outlets

Dimensions

H x W x D (in.)

Weight

(lbs)

PQC11007 78VA 120 0.7 TB 3% 96% 2 3.50 x 4.25 x 6.75 5
PQC1101 120VA 120 1.0 TB 3% 96% 2 3.50 x 4.25 x 6.75 5
PQC1101.5 180VA 120 1.5 TB 3% 96% 2 3.50 x 4.25 x 6.75 6
PQC1102 240VA 120 2 TB 3% 96% 2 3.50 x 4.25 x 6.75 7
PQC1104 360VA 120 3.4 TB 3% 96% 4 4.00 x 5.00 x 7.50 10
PQC1105 480VA 120 4.2 TB 3% 96% 4 4.00 x 5.00 x 7.50 18
PQC1106 600VA 120 5 CB 3% 96% 4 4.00 x 8.00 x 11.75 20
PQC1107 720VA 120 6 CB 3% 96% 4 4.00 x 8.00 x 11.75 21
PQC1108 840VA 120 6.7 CB 3% 96% 4 4.00 x 8.00 x 11.75 23
PQC1110 1000VA 120 8.4 CB 3% 96% 6 6.50 x 10.50 x 16.00 36
PQC1115 1500VA 120 12 CB 3% 96% 6 6.50 x 10.50 x 16.00 39
PQC1120 2000VA 120 16 CB 3% 96% 6 6.50 x 10.50 x 16.00 42

 

Medical Grade Units- (UL 544 Listed)

 

Model

Power Rating

Voltage

Load Capacity Amps

Conditioner Protection Method*

Load Regulation +/-  %

Efficiency

Number of Outlets

Dimensions

H x W x D (in.)

Weight

(lbs)

PQC1102-MED 240VA 120 2 TB 3% 96% 2 3.50 x 4.25 x 6.75 13
PQC1104-MED 360VA 120 3 TB 3% 96% 2 3.50 x 4.25 x 6.75 14
PQC1105-MED 480VA 120 4 TB 3% 96% 4 4.00 x 5.00 x 7.50 17
PQC1106-MED 600VA 120 5 TB 3% 96% 4 4.00 x 5.00 x 7.50 18
PQC1107-MED 720VA 120 6 CB 3% 96% 4 4.00 x 8.00 x 11.75 20
PQC1108-MED 840VA 120 7 CB 3% 96% 4 4.00 x 8.00 x 11.75 22
PQC1110-MED 1000VA 120 8.3 CB 3% 96% 4 4.00 x 8.00 x 11.75 32
PQC1112-MED 1200VA 120 10 CB 3% 96% 6 6.50 x 10.50 x 16.00 38
PQC1115-MED 1400VA 120 12 CB 3% 96% 6 6.50 x 10.50 x 16.00 43
PQC1120-MED 2000VA 120 16 CB 3% 96% 6 6.50 x 10.50 x 16.00 52

Other combinations of input and output voltages, 50/60Hz, and three phase units available.

  • Impulse and Spike Protection--   All systems will withstand and protect against worst-case powerline disturbances, as defined by ANSI/IEEE C62.41-1980 category A and B ringwave and impulse, up to 600V. With an input of 5000V category A ringwave, let-through of high frequency noise will be <10V NM and 0.5V CM, regardless of phase angle.  

  • Reliability-- All units built to UL 1012 standard.

  • Warranty--All units include a standard 5-year warranty.

  • *Protection-- (Column 5 above) TB = Thermal breaker.   CB = Circuit Breaker.                                     

Home | Locations |   Power Quality Profile   | More About Us  | Products  | Power Quality Training | Power Quality Request Form

 Back